The relay module is single‑channel, it is not interfered by additional circuits when in use, and is safe and stable.
The power supply voltage is 12V, which can control or AC loads within 5A to meet more application requirements.
The relay module can be used as a development board to control solenoid valves, water pumps, motors, light strips, etc.
Item Type: Relay Module
Material: Resin
Power Supply Voltage: 12V
Model: YYC-2S 12V
Button Trigger: ( Trigger: - and IN- are short-circuited, + and IN+ are connected to the button)
1. Function List:
P-11: Jog (to pull in the signal relay, the signal disappears and the relay stops)
P-12: Self-locking (turn on the signal relay once, and stop the signal relay again)
P-13: Give the signal, and the relay will automatically stop after closing for A second; triggering is invalid during the delay period
P-14: Give the signal, the relay will stop automatically for A second; trigger to re-timing during the delay period
P-15: Give the signal, the relay will stop automatically for A second; during the delay period, the superposition timer will be triggered
P-16: Give the signal, and the relay will stop automatically for A second; trigger reset during the delay period
P-17: Give the signal, the relay is closed, the input signal is disconnected, and the power is turned off after the start of timing A second, and the signal is kept output during the delay period, and the timing stops
P-18: After the power is turned on, the relay will be closed immediately, and the power will be turned off after a delay of A seconds; until the power on
P-21: Give the signal, after a delay of A second, the relay is closed
P-22: Give the signal, after more than A second, the relay is closed, the signal disappears, and the relay stops
P-23: After the signal disappears for more than A seconds, the relay is closed, there is a signal, and the relay stops
P-24: There is a signal. After A second, the relay is closed. After the signal disappears for more than A second, the relay stops.
P-25: There is a signal. After A second, the relay is closed. When there is another signal for more than A second, the relay stops.
P-26: When there is a signal, the relay will stop after closing for A second, and when the signal disappears, the relay will stop after closing again for A second.
P-27: If there is a pulse signal, the relay stops; if there is no pulse signal, the relay will be closed for A second; (the signal continues or the signal disappears will be regarded as no pulse signal)
P-28: After power-on, after a delay of A seconds, the relay will be closed until the power is off
P-31: After power on, the relay is closed for A second, disconnected for B second, infinite ; power off stops
P-32: When there is a signal, start P-31 infinite ; when the signal disappears, terminate the
P-33: Give a signal to start P-31 infinite ; give another signal to terminate the
P-34: After power-on, the relay will be closed after a delay of A seconds, and stop after being closed for B seconds
P-35: There is a signal, after a delay of A second, the relay will be closed, and the relay will be closed after being closed for B seconds.
P-36: When there is a signal, after A second, the relay will be closed, and after B second, the relay will stop, the signal disappears, and the timer will be cleared and stopped.
P-37: If there is a signal, the relay will stop automatically for A second when the relay is closed, and then it will count for B seconds after it stops. The signal trigger is invalid within the time A+B.
P-38: When there is a signal, the relay will automatically stop when it is closed for A second, and after stopping and counting for B seconds, it will stop automatically when it is closed again for A second.
P-41: No action when there is a signal; trigger when the signal disappears; the relay is disconnected after a delay of A time
P-42: The signal disappears, after delaying time A, the relay wo