Label:Yes
[2] - LOW POWER DRAW
[4] - 2 TRIGGER MODES
Comes with three input ports for motor direction: Forward (FWD), Reverse (REV), and Stop (STOP).
[1] - DUAL POWER INPUT
Set delay timing from 0.1-999.9 seconds, 1-9999 seconds, or 1-9999 minutes - covering both short bursts and long intervals.
Normal Mode draws 41mA on standby and 83mA when running. Energy-Saving Mode drops to 7mA on standby and 44mA when running.
Features dual power options (use one source at a time): Power supply 1 runs on DC 6.5-25V; Power supply 2 runs on DC 5V.
Switch between Low-Pulse trigger mode and Low-Level trigger mode to match your control signal needs.
[5] - WIDE DELAY RANGE
[3] - 3 CONTROL INPUTS
Specification:
Power supply: DC 6.5-25V, DC 5V
Working current: 83mA
Standby current: 41mA
Relay load current: <5A
Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes
Size: 80*50*19mm(3.15*1.97*0.75in)
Material:PCB
Color: Multicolor
Weight: Approx. 51g/1.8oz
Port:
DC 5.5MM(0.22in) female : Power supply 1, DC 5V power supply.
VIN: Power 2 positive, DC 6.5-25V power supply
GND: Power supply 2 negative
FWD: Forward input control (partial Function-Mode is invalid)
REV: Reverse input control (partial Function-Mode is invalid)
STOP : Stop input control (partial Function-Mode is invalid)
M+: Motor positive
M-: Motor negative
P+: Positive terminal for motor power supply
P-: negative terminal for motor power supply
Trigger mode:
1 low pulse trigger (falling edge trigger)
2 low level trigger (rising edge trigger)
Timer:
T1: Forward timer
T2: Reverse timer
T3: Stop timer
Time unit : 0.1 second, 1 second, 1 minute
Relay action:
Motor forward : Relay 1 is ON, relay 2 is OFF, and the F LED indicator is flashing.
Motor reverse : Relay 1 is OFF, relay 2 is ON, and the R LED indicator is flashing..
Motor stop : Relay 1 is OFF, relay 2 is OFF, and the S LED indicator is flashing.
Factory settings:
Press the "++" and "--" buttons simultaneously for 5 seconds.
Energy-saving mode:
Press and hold the "OK" button for 5 seconds to enter the "Energy-saving mode". Press and hold the "OK" button again for 5 seconds to exit the "Energy-saving mode". Energy saving mode just turns off the digital tube and LED indicator, and other functions are normal.
Function mode:
F-01
After power-on, the motor is forward T1 time; then the motor stops T3 time; then the motor reverse T2 time; so it is repeated Nx times. When the STOP port is triggered, the motor stops working immediately. (FWD, REV port is invalid)
F-02
This function is a F-01 variant. F-01 is run directly after power-on, but F-02 needs to trigger FWD or REV port to run.
F-11(Trigger reversible 1)
Trigger the FWD port, the motor is forward T1 time, and automatically stops (in order to protect the motor, during the delay period, trigger the REV port to stop T3 time and then reverse T2 time, trigger FWD port to re-time T1).
Trigger the REV port, the motor is reverse T2 time, and automatically stops (in order to protect the motor, during the delay period, the FWD port is triggered to stop the T3 time and then the T1 time is forward, and the REV port is re-timed T2).
When the STOP port is triggered, the motor stops immediately, regardless of whether the motor is forward or reverse.
F-12(Trigger reversible 2)
Trigger the FWD port, the motor is forward T1 time and stops automatically (during the delay period, except for triggering STOP port, the other ports are invalid).
Trigger the REV port, the motor is reverses T2 time, and automatically stops (during the delay period, except for triggering STOP port, the other ports are invalid).
When the STOP port is trigger, the motor stops immediately, regardless of whether the motor is forward or reverse.
F-21
When the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops.
When the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops.
In this mode, the FWD and REV ports cannot be connected low level at the same time, and the STOP port is invalid.
F-22
When the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops.
When the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops.
In this mode, the FWD and REV ports cannot be connected low level at the same time, triggering the STOP port, the motor stops immediately.
Parameter setting:
There are three menus: Work Menu, Function Menu, Parameter Menu.
Package list:
1 x Motor Controller board
Note:
1.When entering the "Function Menu" or "Parameter Menu", the module still works normally (countdown and the trigger is running normally). The set parameters are valid only after being powered on again.
2.Cycle times: no cycle, 2-99 cycles, always cycle.
3.Three indicators: forward indicator(F LED), reverse indicator(R LED), stop indicator(S LED).Relay load current, recommended less than 5A.
4.This is a multi-function DC/AC motor forward and reverse controller with multiple control modes. Many control functions can be derived through reasonable settings.