Rated short-circuit breaking capacity Icn: 6 kA
Rated switching voltage Ue (AC): 230 / 400 V
Rated operating short-circuit breaking current Ics: 6 kA
Min./max. value of the AC current at which the delayed protection operates: 1.13 / 1.45 In
Min./max. value of the AC current at which the instantaneous protection operates: 3 / 5 In
Rated breaking capacity short-circuit breaking capacity Icn below 230V AC according to IEC 60898-1: 6 kA
Rated ultimate short-circuit breaking capacity Icu for ETIM (PN-EN 60947-2): 6 kA
Current / Temperature
Rated current at temperature -25°C: 22.2 A
Rated current at temperature -20°C: 21.69 A
Rated current at temperature -15°C: 21.19 A
Rated current at temperature -10°C: 20.89 A
Rated current at temperature -5°C: 20.17 A
Rated current at temperature 0°C: 19.66 A
Rated current at temperature 5°C: 19.16 A
Current Rated current at 10°C: 18.65 A
Rated current at 15°C: 18.14 A
Rated current at 20°C: 17.63 A
Rated current at 25°C: 17.13 A
Rated current at 30°C: 16 A
Rated current at 35°C: 16.11 A
Rated current at 40°C: 15.6 A
Rated current at 45°C: 15.1 A
Rated current at 50°C: 15 A
Rated current at 55°C: 14.08 A
Rated current at 60°C: 13.57 A
Rated current Rated current at 65°C: 13.07 A
Rated current at 70°C: 12.56 A
Current correction factor
Rated current correction factor for 2 devices installed side by side: 1
Rated current correction factor for 3 devices installed side by side: 0.95
Rated current correction factor for 4 or 5 devices installed side by side: 0.9
Rated current correction factor for 6 devices installed side by side: 0.85
Correction factor of the instantaneous release at a frequency of 100 Hz: 1.1
Correction factor of the instantaneous release at a frequency of 200 Hz: 1.2
Correction factor of the instantaneous release at a frequency of 400 Hz: 1.5
Correction factor of the instantaneous release at a frequency of 60 Hz: 1
Frequency (range to ETIM): 50 to 60 Hz
Electrical durability (number of cycles): 4000
Mechanical resistance (number of cycles): 20000
Installation / Mounting
Product mounting position 360°: yes
Cross-section of flexible wire (stranded) in the terminal: 1 / 25mm2
Cross-section of rigid wire (wire) in the terminal: 1 / 35mm2
Capacity of input/output terminal for rigid wire (wire): 1 / 35 mm2
Capacity of input/output terminal for flexible wire (stranded): 1 / 25 mm2
Conditions of use
Pollution degree according to IEC 60664 / IEC 60947-2.: 2
Energy limitation class I2t.: 3
Storage/transport temperature: -25…80 °C
MCB Circuit breaker Icn=6000A 1P B 16A
Number of protected poles: 1
Number of poles: 1 P
Pole configuration: 1 P
Tripping characteristic: B
With disconnectable N pole: no
Supply voltage type: AC
Frequency: 50/60 Hz
Rated insulation voltage Ui: 500 V
Rated surge voltage withstand Uimp: 4000 V
Rated current In: 16 A
Total power loss for rated current: 2.44 W
Power loss per pole for rated current: 2.44 W
Product depth: 70 mm
Product height: 83 mm
Product width: 17.5 mm
Tightening torque: 2.8 Nm
Type of connection: stainless steel screw
Standard: EN 60898-1
European WEEE Directive: applicable
Degree of protection: IP20
Operating temperature: -25…70 °C