Features:
Writing applications in ladder language support GXDeveloer, GXWORK2.
Support for humanmachine interface links, the application is exactly the same as FX3U.
Support ladder programming, download, monitor.
The programming port is a port for program download and communication with the human machine interface.
This PLC adopts industrialgrade 32bit MCU with strong antiinterference, and its running speed far exceeds the original FX3U.
This PLC transmission baud rate is 38400.
14point input and 10transistor output of the board.
Y0Y3 transistor can output up to 100K pulse.
Y4Y7 transistor can output up to 12K pulse.
Y0Y10 can also be used for ordinary output, which can drive stepping, solenoid valve, cylinder and other DC 24V load.
The board is powered by DC 24V. Do not input AC or 220V voltage.
Specification:
Baud Rate:38400
Power Source:24VDC
Input power
DC 24V
Number of steps
8000 steps; 2 communication ports: 1 RS232 (DB9 serial communication port is FX3u protocol 38400, 7, E, 1; 1 RS485 (485 option) (communication protocol can be set D8120)
Input point X component
XOX27, DC24 input, active low. X05 is the highspeed counting input port (12KHZ)
Input point Y component
YOY3 is the transistor output, the transistor output current is 500mA, plus the freewheeling diode can reach 4A; YOY3 is 4 channel 100K pulse output, the output current is 500mA, plus the freewheeling diode can reach 4A.; Y4~Y11 is the transistor common output Can directly drive 24V3A load
Analog input
6 analog inputs, 12bit accuracy, (3 voltages 010V, 3 currents 020MA); read analog with RD3A instructions
Analog output
2 analog outputs, 12bit accuracy, output voltage: 010V. Output analog voltage with WR3A command
Intermediate relay M
MOM3071, the powerdown storage range can be set to MOM1023, the default M500M1023
Step point S
S01023, the powerdown storage range can be set to S0S1023, the default S500S9999
100Ms timer
TOT199, cumulative powerdown save T184T199
10Ms timer
T200T249, cumulative powerdown save T246T249
1Ms timer
T250T383, where T250255 is cumulative
16bit counter
COC199, save power C100199
32bit counter
C200C219, save power C220C234
32bit highspeed counter
C235255; C235240 is a singlephase counter, no multiplier; C241240 is a singlephase counter, 2 times the frequency; C247249 is a twophase counter, no multiplier; C250252 is a twophase counter, 2 times Frequency; C253255 is a twophase counter, 4 times frequency
Register D
DOD7999, the powerdown storage range can be set to DO7999.
Indirect addressing pointer V, Z
VO7, Z07
P subroutine jump number
PO63
I interrupt
XO5 is interrupted outside. Timer interrupt (1MS is the unit). Counter interrupt
Special M component
M8000 is normally closed when running, M8002 is powered on pulse, M8011 is 10Ms pulse, M8012 is 100Ms pulse, M8013 is 1s pulse, M8014 is minute pulse.
Mnemonic, name
Function
LD
Operation starts normally open contact
LDI
Operation starts normally closed contact
LDP
Rising edge detection operation starts
LDF
The falling edge detection operation starts
AND
Series normally open contacts
ANI
Series normally closed contacts
ANDP
Check the serial connection on the upper edge
ANDF
Falling edge detection serial connection
OR
Parallel normally open contact
ORI
Parallel normally closed contact
ORP
Rising edge detected parallel connection
ORF
Falling edge detection parallel connection
ANB
Series connection between circuit blocks
ORB
Parallel connection between circuit blocks
OUT
Coil output drive
SET
Coil action remains
RST
Remove line wet motion retention
PLS
Coil rising edge output
PLF
Coil falling edge output
ALT
Alternate output
MC
Common string connection point with coil command
MCR
Common contact release command
MPS
Operational storage
MRD
Storage readout
MPP
Storage readout and reset
INV
The operation result is reversed
END
End of program
4 step ladder instructions
STL
Step ladder start
CALL
Call subroutine
RET
Step ladder end
SRET
Subroutine return
Package List:
1 x PLC Controller
.
Note:
Please note that the new type and old type of this product will be sent randomly, and make sure you will not mind before ordering.
Writing applications in ladder language support GX?Develoer, GX?WORK2.
Support for human?machine interface links, the application is exactly the same as FX3U.
The programming port is a port for program download and communication with the human machine interface.
This PLC adopts industrial?grade 32?bit MCU with strong anti?interference, and its running speed far exceeds the original FX3U.
14?point input and 10?transistor output of the board.