Feature:
1. User Switch: In the standby state, hold down the set button for about 1 second to switch users. The sphygmomanometer can automatically record the date and time of each measurement.
2. Automatic Measurement: The blood pressure function of this measuring instrument is a fully automatic measurement arm type electronic sphygmomanometer, which can simultaneously measure systolic pressure (high pressure), diastolic pressure (low pressure) and pulse number through the principle of pressure oscillation.
3. Blood Pressure Measurement: Blood pressure measurement is suitable for measuring adult diastolic blood pressure, systolic blood pressure and pulse rate by wave method, and its value is for diagnostic reference.
4. Blood Glucose Measurement; Suitable for use with matching blood glucose test strips for quantitative detection of glucose concentration in whole blood of human capillaries. (except newborns).
5. Convenient and Fast: Blood pressure and blood sugar testing at the same time, there is no need to go to the hospital, and it is more convenient and fast to monitor the physical condition anytime and anywhere.
6. Multiple Functions: Intelligent pressure, blood sugar measurement, voice broadcast, 120 groups of memory, irregular rate prompt function, time display.
Specification:
Item Type: Blood Pressure Monitor
Weight: 455g/16oz
Material: ABS nylon
Model: BG A8
Product Size: 150 x 75 x 30mm/5.9 x 2.95 x 1.2in
Battery (Shipped without Battery) : 4 x AAA dry batteries
Power Supply: USB DC5V power supply (shipped without power cord) or AAA battery, two options
Measurement Method: oscilloscope measurement method
Blood Pressure Measurement:
Blood Pressure Measurement Range:
Blood Pressure :0kPa~34.7kPa(0mmHg~260mmHg)
Pulse :(40~200) beats/min
Memory: can automatically store 120 groups of memory for 2 users
Arm Circumference: 22-32cm/8.7-12.6in
Resolution: 0.1kPa(1mmHg)
Static Pressure :±0.4kPa(±3mmHg)
Pulse Number: within ±5% of the reading value
Blood Sugar Measurement:
Blood Glucose Measurement Range: 20~600mg/dL(1.1~33.3mmol/L)
Reaction Time: (6±2) s
Blood Volume: 1µL(microliter)
Memory: 500 sets of latest measurements can be stored
Armband Set:
1. Insert one end of the armband through the metal ring to make the armband into a cylinder. If the armband is already cylindrical, you can skip this step.
2. Place the arm strap on your upper left arm, with the hose facing toward your palm.
3. Wrap the armband around the left arm and make sure that the bottom of the armband is 2-3cm away from the elbow joint. The rubber tube should be in a straight line with the middle finger.
4. Tighten the armband and stick it in place.
5. Leave a two finger gap between the arm and the armband, otherwise it will affect the accuracy of the measurement.
6. Make sure the armband is comfortably placed on the arm, not too tight, and place the arm on the table, palm facing so that the armband is at heart level. Make sure the armband on your arm is smooth and wrinkle free.
7. Before the formal measurement, please sit quietly for 5 minutes.
Suggestion: If it is not possible to put the armband on the left arm, put the armband on the right arm. It is recommended to use the same arm measurement in the future.
Settings:
Unit of Measurement, Record Deleted
The LCD screen displays the following:
1. Display test results in units of measurement, mg/dL or mmo/L.
2. The Read record mode is displayed.
3. Enter the setting mode.
4. Display as quality control liquid mode.
5. The display of the blood drop icon indicates that the measuring instrument is ready to inhale the blood sample.
6. Show the average blood sugar.
7. Display hours.
8. Display minutes.
Key Function:
1. Test Paper Slot: Insert the test paper into the test paper slot, and the measuring instrument will automatically turn on.
2.LCD Display Area: Symbols and simple messages guide you through the test, showing blood glucose readings.
3.M Key: Power on, power off and view the record value key
4.C Key: Set mode
5. Battery Area: Battery installation position..
Package List:
25 x Test Strip(1 Bottle)
1 x Armband 1 x Blood Pressure and Blood Sugar Tester Machine 1 x Instructions
Note:
1. Do not wear the blood collection pen and needle when shipping, as for the use of the process of blood collection can be their own embroidery needle slightly alcohol wipe disinfection after direct blood collection can also test blood sugar;2. If there is no input action 2 minutes after the test paper is inserted or 60 seconds after no test paper is inserted, the glucose meter will automatically shut down.