Reduce downtime - Detect leaks without taking equipment offline.
The Fluke 368 True-RMS Leakage Current Clamp Meter records and documents detected leaks and compares readings between measurements, preventing unplanned downtime and identifying intermittent GFCI and RCD tripping. Measurements can be taken while the instrument is live.
The Fluke 368's wide 40mm opening accommodates measurements on large conductors. The clamp jaws are fully shielded, ensuring accurate detection of even the smallest leaks and minimizing external electromagnetic interference.
□Key Features□
- True RMS measurement provides high accuracy for complex waveforms other than sine waves.
- Aperture: 61 mm
- Measures up to 60 A with a maximum resolution of 1 μA.
- Selectable filter function eliminates unwanted noise.
- Measures maximum, minimum, and average values, and supports hold function.
- LED work light on the front of the unit allows use even in dark wiring cabinets.
- Backlit display. Backlight and auto-off functions extend battery life.
・CAT III 600V safety rating
・Reduced downtime - Detect leaks without taking equipment offline.
□Electrical Specifications□
[Measurement Function] AC
[AC Ampere Range] 3mA, 30mA, 300mA, 3A, 30A, 60A
[Range Selection] mA / A: Manual Selection
______3 mA / 30 mA / 300 mA: Automatic Selection
______3 A / 30 A / 60 A: Automatic Selection
[Range/Resolution] 3 mA*1 / 0.001 mA
______30 mA / 0.01 mA
______300 mA / 0.1 mA
_______3 A / 0.001 A
______30 A / 0.01 A
______60 A / 0.1 A
[Accuracy - Filter Enabled (40 to 70 Hz), Filter Disabled (40 to 1 kHz) *2]
____3 mA to 30 A: 1% + 5 counts
____60 A: 2% + 5 counts
[Frequency] 40 Hz to 1 kHz
[Crest Factor] = "3"
Accuracy is valid for one year after calibration. Accuracy is expressed as ± (% of reading + counts). Reference conditions are 23 ± 5°C (73°F ± 5°F) and maximum relative humidity of 80%.
*1. Minimum value is 10 μA rms.
*2. TC/°C out of range: 18-28°C, 0.02 +1
□ Physical Specifications □
[Display (LCD)] Digital readings: 3300 counts
[Screen Refresh Rate] 4 times/second
[Maximum Conductor Diameter] 40 mm
[Dimensions] 257 x 116 x 46 mm
[Weight] 600 g
[Batteries] 2 x AA, IEC LR6, NEDA 15A, Alkaline
[Battery Life] Battery life is over 150 hours (without backlight or spotlight).
[Automatic Shutdown] The meter automatically shuts down after 15 minutes of inactivity.
□ Safety and Environmental Specifications □
[General Safety Specifications] IEC 61010-1: Pollution Degree 2
[Measurement Safety] IEC 61010-2-032: CAT III 600 V/CAT IV 300 V
[Operating Temperature] -10°C to +50°C
Storage Temperature: -40°C to +60°C
Operating Humidity: Non-condensing (<10°C)
90% Relative Humidity (10 to 30°C)
75% Relative Humidity (30 to 40°C)
45% Relative Humidity (40 to 50°C)
Protection Class: IEC 60529: IP30 (jaw closed)
Operating Altitude: 2000m
Storage Altitude: 12000m
Current Sensor Operating Category: IEC 61557-13: Class 2, ≤ 30A/m
True RMS provides high accuracy for complex waveforms other than sine waves.
Aperture: 40 mm
Measures up to 60 A with a maximum resolution of 1 μA.
Selectable filter function eliminates unwanted noise.
Measures maximum, minimum, and average values with hold function.